Home | honor | Jobs | Chinese
NT(NH)RT16 Serises Fuses
Categories:Low Series   
 
NT-Fuse link
Features
According to IEC60269、DIN43620、GB13539and CESafetyROHS certificate.
Rated voltage:AC500V/690V or DC440V
Rated current:2A~1250A
Exception:Size 00 with DC 250V
Operating class:
①gL/gG for cable and conductor protection
②aM for motor protection
③aR for semiconductor protection
Finely graduated selectivity
Rated breaking capacity:AC 120kA(Size 00:AC 50kA)
 
Product photo

Size

In

A

Order No.
Fig。
Weight
(g)

Operating Class(gL/gG)

Operating class(aM)
Operating class(aR)

NT00C
(RT1-00C)

2
4
6
10
16
20
25
32
35
40
50
63
80
100
002GNT00C
004GNT00C
006GNT00C
010GNT00C
016GNT00C
020GNT00C
025GNT00C
032GNT00C
035GNT00C
040GNT00C
050GNT00C
063GNT00C
080GNT00C
100GNT00C
002MNT00C
004MNT00C
006MNT00C
010MNT00C
016MNT00C
020MNT00C
025MNT00C
032MNT00C
035MNT00C
040MNT00C
050MNT00C
063MNT00C
080MNT00C
100MNT00C
002RNT00C
004RNT00C
006RNT00C
010RNT00C
016RNT00C
020RNT00C
025RNT00C
032RNT00C
035RNT00C
040RNT00C
050RNT00C
063RNT00C
080RNT00C
100RNT00C
Fig.1.1

145
NT00
(RT16-00)
2
4
6
10
16
20
25
32
40
50
80
100
125
160
002GNT00
004GNT00
006GNT00
010GNT00
016GNT00
020GNT00
025GNT00
032GNT00
040GNT00
050GNT00
080GNT00
100GNT00
125GNT00
160GNT00
002MNT00
004MNT00
006MNT00
010MNT00
016MNT00
020MNT00
025MNT00
032MNT00
040MNT00
050MNT00
080MNT00
100MNT00
125MNT00
160MNT00
002RNT00
004RNT00
006RNT00
010RNT00
016RNT00
020RNT00
025RNT00
032RNT00
040RNT00
050RNT00
080RNT00
100RNT00
125RNT00
160RNT00
Fig.1.1
180
For dimension drawings,see pages 9.
For characte ristic curves,see pages 11.
 

 

 
NT-Fuse link(Continuation)
 

Product photo

Size

In

A

Order No.
Fig.
Weight
(g)
Operating class(gL/gG)
Operating class(aM)
Operating class(aR)
NT0
4
6
10
16
20
25
32
40
50
63
80
100
125
160
004GNT0
006GNT0
010GNT0
016GNT0
020GNT0
025GNT0
032GNT0
040GNT0
050GNT0
063GNT0
080GNT0
100GNT0
125GNT0
160GNT0
004MNT0
006MNT0
010MNT0
016MNT0
020MNT0
025MNT0
032MNT0
040MNT0
050MNT0
063MNT0
080MNT0
100MNT0
125MNT0
160MNT0
004RNT0
006RNT0
010RNT0
016RNT0
020RNT0
025RNT0
032RNT0
040RNT0
050RNT0
063RNT0
080RNT0
100RNT0
125RNT0
160RNT0
Fig.1.2
240
NT1
63
80
100
125
160
200
224
250
063GNT1
080GNT1
100GNT1
125GNT1
160GNT1
200GNT1
224GNT1
250GNT1
063MNT1
080MNT1
100MNT1
125MNT1
160MNT1
200MNT1
224MNT1
250MNT1
063RNT1
080RNT1
100RNT1
125RNT1
160RNT1
200RNT1
224RNT1
250RNT1
Fig.1.2
450
NT2
80
100
125
160
200
224
250
300
315
355
400
080GNT2
100GNT2
125GNT2
160GNT2
200GNT2
224GNT2
250GNT2
300GNT2
315GNT2
355GNT2
400GNT2
080MNT2
100MNT2
125MNT2
160MNT2
200MNT2
224MNT2
250MNT2
300MNT2
315MNT2
355MNT2
400MNT2
080RNT2
100RNT2
125RNT2
160RNT2
200RNT2
224RNT2
250RNT2
300RNT2
315RNT2
355RNT2
400RNT2
Fig.1.2
670
NT3
300
315
355
400
425
500
630
300GNT3
315GNT3
355GNT3
400GNT3
425GNT3
500GNT3
630GNT3
300MNT3
315MNT3
355MNT3
400MNT3
425MNT3
500MNT3
630MNT3
300RNT3
315RNT3
355RNT3
400RNT3
425RNT3
500RNT3
630RNT3
Fig.1.2
900
NT4
630
800
1000
1250
630GNT4
800GNT4
1000GNT4
1250GNT4
630MNT4
800MNT4
1000MNT4
1250MNT4
630RNT4
800RNT4
1000RNT4
1250RNT4
Fig.1.3
2200
For characteristic curves,see pages 11.
For dimension drawings,see pages 9
 


 
NT-Fuse bases
For NT and NH fuse links
According to IEC60269、DIN43620、GBl3539 and CE Safety、
ROHS ce rtiflcate
Rated voltage:AC500V/AC690V or for semiconduct6r-protecting
-inse rt-part AClOOOV
 
Product Photo
Size
0rder N0.
Fig.

Weiaht
(g)
Rated Current 160A
NTOO
Sistl01
single—pole
for double busbar termlnal connection
NTOOFB
Fig.1.4
225
triple—pole
for double busbar termlnal connectlon
NTOOFB3P
Fig.1.8
516
NTO
Sist160
single-pole
for double busba r termlnal connectlon
NTOFB
Fig.1.5
41O
250ARated Current 250A
NTl
Sist201
single-pole
fo r double bUSba r te rmlnal connectionl)300
NTlFB
Fig.1.6
740
400A/Rated Current 400A
NT2
Sist401
slngle—pole
for double busbar termInal connectionl)2×40×5
NT2FB
Fig.1.6
1110
额定电流630A/Rated Current 630A
NT3
Sist601
slngle-pole
with screw-type terminal connection 2×50×8
NT3FB
Fig.1.6
1310
额定电流1250A/Rated Current 1250A
NT4
Sistl001
single-pole
with screw—type terminal connection 2×50×8
NT4FB
Fig.1.6
2520
Fo rdimension d rawings,see pages 9
 

 

 
NT-Fuse link
Features
According to IEC60269、DIN43620、GB13539and CESafetyROHS
certificate.
Rated voltage:AC500V/690V or DC440V
Rated current:2A~1250A
Exception:Size 00 with DC 250V
Operating class:
①gL/gG for cable and conductor protection
②aM for motor protection
③aR for semiconductor protection
Finely graduated selectivity
Rated breaking capacity:AC 120kA(Size 00:AC 50kA)
 

Product photo

Size

In

A

Order No.
Fig。
Weight
(g)

Operating Class(gL/gG)

Operating class(aM)
Operating class(aR)

NH00C

2
4
6
10
16
20
25
32
35
40
50
63
80
100
002GNH00C
004GNH00C
006GNH00C
010GNH00C
016GNH00C
020GNH00C
025GNH00C
032GNH00C
035GNH00C
040GNH00C
050GNH00C
063GNH00C
080GNH00C
100GNH00C
002MNH00C
004MNH00C
006MNH00C
010MNH00C
016MNH00C
020MNH00C
025MNH00C
032MNH00C
035MNH00C
040MNH00C
050MNH00C
063MNH00C
080MNH00C
100MNH00C
002RNH00C
004RNH00C
006RNH00C
010RNH00C
016RNH00C
020RNH00C
025RNH00C
032RNH00C
035RNH00C
040RNH00C
050RNH00C
063RNH00C
080RNH00C
100RNH00C
Fig.1.1

150
NH00
2
4
6
10
16
20
25
32
40
50
80
100
125
160
002GNH00
004GNH00
006GNH00
010GNH00
016GNH00
020GNH00
025GNH00
032GNH00
040GNH00
050GNH00
080GNH00
100GNH00
125GNH00
160GNH00
002MNH00
004MNH00
006MNH00
010MNH00
016MNH00
020MNH00
025MNH00
032MNH00
040MNH00
050MNH00
080MNH00
100MNH00
125MNH00
160MNH00
002RNH00
004RNH00
006RNH00
010RNH00
016RNH00
020RNH00
025RNH00
032RNH00
040RNH00
050RNH00
080RNH00
100RNH00
125RNH00
160RNH00
Fig.1.1
185
For dimension drawings,see pages 9.
For characte ristic curves,see pages 11.
 

 
NT-Fuse link (Continuation)
 

Product photo

Size

In

A

Order No.
Fig.
Weight
(g)
Operating class(gL/gG)
Operating class(aM)
Operating class(aR)
NH0
4
6
10
16
20
25
32
40
50
63
80
100
125
160
004GNH0
006GNH0
010GNH0
016GNH0
020GNH0
025GNH0
032GNH0
040GNH0
050GNH0
063GNH0
080GNH0
100GNH0
125GNH0
160GNH0
004MNH0
006MNH0
010MNH0
016MNH0
020MNH0
025MNH0
032MNH0
040MNH0
050MNH0
063MNH0
080MNH0
100MNH0
125MNH0
160MNH0
004RNH0
006RNH0
010RNH0
016RNH0
020RNH0
025RNH0
032RNH0
040RNH0
050RNH0
063RNH0
080RNH0
100RNH0
125RNH0
160RNH0
Fig.1.2
255
NH1
63
80
100
125
160
200
224
250
063GNH1
080GNH1
100GNH1
125GNH1
160GNH1
200GNH1
224GNH1
250GNH1
063MNH1
080MNH1
100MNH1
125MNH1
160MNH1
200MNH1
224MNH1
250MNH1
063RNH1
080RNH1
100RNH1
125RNH1
160RNH1
200RNH1
224RNH1
250RNH1
Fig.1.2
475
NT2
80
100
125
160
200
224
250
300
315
355
400
080GNH2
100GNH2
125GNH2
160GNH2
200GNH2
224GNH2
250GNH2
300GNH2
315GNH2
355GNH2
400GNH2
080MNH2
100MNH2
125MNH2
160MNH2
200MNH2
224MNH2
250MNH2
300MNH2
315MNH2
355MNH2
400MNH2
080RNH2
100RNH2
125RNH2
160RNH2
200RNH2
224RNH2
250RNH2
300RNH2
315RNH2
355RNH2
400RNH2
Fig.1.2
700
NT3
300
315
355
400
425
500
630
300GNH3
315GNH3
355GNH3
400GNH3
425GNH3
500GNH3
630GNH3
300MNH3
315MNH3
355MNH3
400MNH3
425MNH3
500MNH3
630MNH3
300RNH3
315RNH3
355RNH3
400RNH3
425RNH3
500RNH3
630RNH3
Fig.1.2
935
NT4
630
800
1000
1250
630GNH4
800GNH4
1000GNH4
1250GNH4
630MNH4
800MNH4
1000MNH4
1250MNH4
630RNH4
800RNH4
1000RNH4
1250RNH4
Fig.1.3
2260
For dimension drawings,see pages 9
For characteristic curves,see pages 11.
 

 

 
NH-Fuse bases
For NT and NH fuse links
According to IEC60269、DIN43620、GB13539 and CE Safety、
ROHS certificate.
Rated voltage:AC500V/AC690V or for semiconductor-protecting-
insert-part AC1000V
 
Product Photo
Size
0rder N0.
Fig.

Weiaht
(g)
160A/Rated Current 160A
NHOO
Sistl01
single—pole
for double busbar termlnal connection
NHOOFB
Fig.1.7
170
NH1
Sist201
single-pole
for double busba r termlnal connectlon
NH1FB
Fig.1.9
50O
400ARated Current 400A
NH2
Sist401
single-pole
fo r double bUSba r te rmlnal connection
NH2FB
Fig.1.10
520
Rated Current 630A
NH3
Sist601
slngle—pole
for double busbar termInal connection
NH3FB
Fig.1.11
760
Rated Current 1250A
NH4
Sist1001
slngle-pole
for double busbar termInal connection
NH4FB
Fig.1.6
2500
Rated Current 400A
NH2
Sist401
single-pole
fo r double bUSba r te rmlnal connection
NH2FB3P
Fig.1.12
3600
1000V/Rated insulation Voltage 1000V
NH Handle
For NH000-NH4
NH-H
FIG.1.13
250
Fo rdimension d rawings,see pages 10
 

 
NT(NH)Fuse link
No.
Size
Fig.
Class rating(A)

Dmensions(mm)

A
B
C
D
E
F
001
NT00C(NH00C)
Fig.1.1
2~100
78
49
15
21
52.5
6
002
NT00(NH00)
Fig.1.1
2~160
78
49
15
28.5
55.5
6
003
NTO(NHO)
Fig.1.2
4~160
122
65
15
29
55.5
6
004
NT1(NH1)
Fig.1.2
63~250
135
68
20
48
60
6
005
NT2(NH2)
Fig.1.2
80~400
150
68
26
60
70.3
6
006
NT3(NH3)
Fig.1.2
300~630
150
68
32
67
82
6
007
NT4(NH4)
Fig.1.3
630~1250
200
80
51
85
112
8
 
NT(NH)Fuse base
No.
,
Size
Fig.
Class rating(A)
Dmensions(mm)
A
B
C
φD
E
F
G
H
008
NTOO(Sist101)
Fig.1.4
160
120
100
30
7
23
60
25
-
009
NTO(Sist160)
Fig.1.5
160
170
150
30
7
35
73
25
-
010
NT1(Sist201)
Fig.1.6
250
200
175
58
9.5
38
82
25
30
011
NT2(Sist401)
Fig.1.6
400
225
200
64
9.5
40
100
25
30
012
NT3(Sist601)
Fig.1.6
630
240
216
64
9.5
40.5
105
25
30
013
NT4(Sist1001)
Fig.1.6
1250
304
260
96
13
44
145
25
45
 


 

 
NH Fuse base

 
Characteristic curves